Monday, December 26, 2011

Honeywell L4064B1469 combination fan and limit furnace control [Misc.] [Misc.]

!±8± Honeywell L4064B1469 combination fan and limit furnace control [Misc.] [Misc.]

Brand : Honeywell | Rate : | Price :
Post Date : Dec 26, 2011 16:08:21 | Usually ships in 1-2 business days


Honeywell model L4064B1469 Combination Fan Limit Furnace Control Closes Fan Open Limit Circuit On Temp Rise. Manual Fan Switch. 3/4 inch Tube Diameter. 200F Stop Set. 65-215F Fan On. 50-200F Fan Off. 100-250F Limit Rng. Super Tradeline. 5 inch Insertion Rigid Mounting. Large Painted Cover., Screw Terminal Adaptors

More Specification..!!

Scooter Sale Off

Thursday, December 22, 2011

C.A.P. TMP-DNe DAY/NIGHT TEMPERATURE CONTROL

!±8± C.A.P. TMP-DNe DAY/NIGHT TEMPERATURE CONTROL


Rate : | Price : $64.00 | Post Date : Dec 22, 2011 17:57:08
Usually ships in 1-2 business days

The TMP-DNe allows you to control the temperature within your growing environment. You can set the day and night temperature independently. The TMP-DNe can be set to either heat or cool. Just connect your equipment, then set the temperature that you wish to maintain. If the temperature varies from your setting, the outlet on the front is activated. The temperature differential can be set at 3, 5 or 7 degrees. Comes with a 12" remote sensor. The TMP-DNe is rated for 15 amps @ 120 volts. 3 year no hassle warranty.

Canon Hdmi Cable Review

Saturday, December 10, 2011

PROCOMP DUAL 9" INCH ELECTRIC FAN & THERMOSTAT RELAY SWITCH 39

!±8± PROCOMP DUAL 9" INCH ELECTRIC FAN & THERMOSTAT RELAY SWITCH 39

Brand : Procomp Electronics | Rate : | Price :
Post Date : Dec 10, 2011 23:24:35 | Usually ships in 1-2 business days


Kit Includes: * 2 Procomp 9" Fans (w/ mounting feet) * 2 Mounting Tie Strap Kits * 1 Derale Thermostat Fan Controller Kit * 12V Reversible Electrical Cooling Fans are ideal for OEM or High Performance applications. * Configured as a puller from the factory, it mounts on the inside and pulls the air through the radiator. * Blades and polarity of the wiring can be reversed and it becomes a pusher fan. * Universal application to fit all makes and models, cars and trucks. * 1500 Total CFMCustomers mount these fans on boats, go-carts, and other off-road and street custom vehicles. The application is only limited to your imagination. Measurements: * Thickness- 1 1/4" at edge, 2 3/4" at center * Height- 9 1/2" * Width- 9 3/4" Derale Electric Thermo Fan Controller * Thermostat is a Single Stage Controller * 3/8" pipe thread water jacket thread-in brass probe. * Activates turn on at 180'F and shuts off at 170'F. * Will work on any 12 volt fan. * Relay is 30/40 amp, heavy duty for fans that draw over 10 amps. * Maximum capacity is 25 amps. * A/C override circuit included. * Designed for single and dual fan setups. * Kit includes thermostat switch, relay w/ wiring & fuse, wire hardware and relay holder screw, installation booklet with diagram.

More Specification..!!

Ugg Sunburst Tall Sand Guide

Friday, December 2, 2011

(Sous) Stu-Vide Simple - Cook Steak with a Hair Dryer - Narrated

Cheap. simple, easy. Use a Hot Water Heater Thermostat to control ac outlet. Plug hair dryer into outlet. (You can also use a 100 Watt lamp bulb as the heat source and a small electric fan to distribute the heat) Place meat in pan and cover with plastic. 3 hours later, a perfectly cooked London Broil. Uses very little power. Fail safe, I assure you. Plans, instructions: PayPal.

Washburn Acoustic Decide Now

Tuesday, November 22, 2011

1991 Ford Mustang LX Supercharged For Sale MISSING REWARD OFFERED IF FOUND

1991 Mustang LX Convertible This mustang is my baby and I really hate to sell it... As you will see below in my list of building my dream car not a corner was cut. The car has 57934 miles on the frame of the car. It's the factory color Titanium Frost Silver with a Cervini Fiberglass Cobra R Hood 17 inch Custom Billet Wheels Budnik Stiletto wrapped in Nitto Z Rated Tires, Ice cold AC, Power steering, brakes. locks, windows, and seats. The car has won many car shows and is a real clean fast car making 420 rear wheel horsepower. Please read the list below and I'll be happy to answer questions and encourage that you come see the car in person. It's one of the rare clean 5.0 Fox body cars out there... 500 OBO or Possible Trade Call 305-942-3777 -Engine- 306 Bullet Small Block built by DSS Racing 8000 Miles on the motor -Forged Pistons set up for Boost- -Screw in Freeze Plugs Block- -Lower End Engine Girdle- -FMS (Ford Motorsports) High Flow Oil Pump- -FMS Timing Chain and Gear Set- -FMS Water Pump and Hose Kit- -FMS Balancer- -FMS 42lbs. injectors- -FMS Fuel Rails- -Granitelle Mass Air- -Anderson Power Pipe with Fender Mount K&N Filter- -Comp Cam- -Victor Jr. EFI Intake by Edelbrock with Spacer Plate- -Complete MSD Ignition System (msd 6al box, coil, and distributor)- -Steeda Plug Wires- -Crane Gold Roller Rockers 1.7- -Air Flow Research AFR O ring Aluminum Heads- -Power dyne Supercharger 8 psi Pulley- -APR Head Bolts and Bolt Kit for the Motor- -DSS Racing 8 quart Oil Pan ...

Best Prices White Mountain Amigo Boots Last Minute Polar Speed Sensor S Series Sony Dvd Vhs Recorder Coupon

Thursday, November 10, 2011

New Hunter Fan Company 44905 Thermostat Universal 7 Day Programmable Touchscreen With Energy Guide

!±8±New Hunter Fan Company 44905 Thermostat Universal 7 Day Programmable Touchscreen With Energy Guide

Brand : Hunter Fan
Rate :
Price : $97.91
Post Date : Nov 10, 2011 20:13:16
Usually ships in 1-2 business days



It's Easy. Universal compatibility means it works on all system types. Screwless, color coded wire terminals, built-in level bulb and all purpose screws mean you can install it in 5 minutes - really. It's Convenient. With 7 Day Programmable Max capability, you can set up to four programs for each day of the week - truly customizing the program to fit your lifestyle. It's Smart. With features exclusive to Hunter, it helps you save money and stay comfortable. The Energy Guide gives you instant savings feedback as you change the settings and the Save Away one-touch override - for times you are away - gives you even more opportunities to save. Finally, our patented Home Today override keeps you comfortable on days when you are normally away. Programmable. Refresh circulating fan for constant fresh air. All-purpose screws - no anchors or drilling required. Home Today one-touch override for days when you are not normally at home. Save Away one-touch override. Refresh circulating fan for constant fresh air. Screwless, color coded wire terminals. Automatically changes between heat and cool. Installs in 5 minutes or less. Keyboard Lock. Maximum contrast white LED backlight for easy reading. Touchscreen. Compatibility: Air conditioning. Up to 2 stage Heat/2 stage Cool systems. Gas, electric and oil furnaces. Gas and oil fired boilers. AC or battery power. Most 24 Volt and Millivolt systems. 2 and 3 wire hot water/radiator systems. Single and two stage heat pumps with auxiliary heat.

Energetics Crosstrainer Right Now Promotional Best Dyson Vacuum Portable Generators For Home Buy

Friday, November 4, 2011

Taking Care of Your Volkswagen

!±8± Taking Care of Your Volkswagen

The cooling system of your Volkswagen vehicle is an important part in order to keep your vehicle operating efficiently. The cooling system maintains the right temperature of your engine through the circulation of coolant through the engine that picks up heat and passing it through the radiator where it is cooled with air. The coolant in turn passes through a thermostat valve to control flow and through a temperature sensor which controls external air cooling fans.

Volkswagen vehicle cooling systems are comprised of three main parts and these are the VW water pump, VW hoses and VW thermostat, radiator and sensors.

Volkswagen Water Pump

The VW water pump handles the VW's cooling system's pumping function which keeps the coolant mixture moving. The basic VW water pump is gear or belt-driven there are also some cases in other cars wherein a secondary electric water pump is used to improved cooling and flow of the coolant mixture. One of the most important parts of the pump's operation is the drive belt which is also known on most new cars as the timing belt. However, on older car models, the pump and the belt are external and run off the main crankshaft pulley using a "V" of flat belt.

The maintenance of VW water pump is done simultaneous with the replacement of the coolant, the drive belt and tension adjustment (external type). The timing belt driven pumps should always be done when replacing the timing belt and tensioner.

Volkswagen Hoses

The VW cooling system involves various hoses which includes the Volkswagen radiator hose, control valves, the heater core and the expansion tank. And since these materials are constantly used and are exposed to heated coolant, these parts deteriorate easily and needs to be change more often.

The maintenance of cooling system piping consists of scheduled replacement of all hoses, replacement of coolant plus the replacement of any unplugged or leaking parts. It is a good idea to have all hoses checked at least twice a year to see whether there are abrasions, flexibility, cracks, and leakage. And of course it is vital that whenever coolant is flushed for replacement or even during engine repairs that hoses should be replaced. Radiator hoses, expansion tanks, heater cores, and control valves are commonly replaced due to leakage or plugging. However it is important that a VW professional should be the one contacted to assess the condition of these parts since they know everything there is to know about Volkswagen components.

Volkswagen Radiator, Thermostat and Sensors

Volkswagen's cooling system's temperature controls include all coolant temperature sensors, radiator or expansion tank cap, thermostat, cooling fan(s) and fan clutch. These cooling parts function independently of the engine but maintain the control over the engine cooling which is made by means of sending control signals to the VW's electronic systems.

The spring loaded valve that opens and closes based on the temperature of the coolant flowing through it is called the thermostat. You can tell that something is wrong with your thermostat when you see a high temperature reading is followed by a drop to normal temperature or a continuously low temperature---this normally indicates a sticking thermostat. Unfortunately, there are other conditions that caused these symptoms and if you are not sure what causing it then better have a VW professional mechanic to check it.

The radiator or expansion tank cap is similarly a spring loaded valve that reacts to system pressure. Its function is to maintain proper system coolant level at predetermined pressures. It should always be replaced with an exact replacement cap with the same pressure setting to obtain optimum function.

A belt-driven fan blade that pulls air through the radiator is usually included on the water pump pulley with a fan clutch to control it. The fan clutch functioned by allowing the fan to turn with the belt at low engine speed and shift to "free-wheel" at higher speeds. A damage fan clutch should not be taken for granted since it may cause your vehicle to overheat.

An electric fan that can function by itself or with an auxiliary mechanical fan is usually equipped for front-wheel-drive Volkswagen. These two types of fans are controlled via a temperature sensor that is found on the radiator specifically on the upper radiator hose or on the thermostat or water pump housing. This sensor is usually an on/off type switch with a fixed temperature setting.

The other common temperature sensors that are found on Volkswagen vehicles include: gauge sender, warning light sender, lambda and/or fuel injection sensor/s and the thermo-time switch. Controlling the engine temperature is critical to obtain high performance and emission control. But unfortunately it is also the system that is one of the most difficult to fix getting a VW professional is highly advised.

On the other hand maintenance of your cooling system sensors is a no sweat task since there is nothing to maintain in the first place, all you have to do is to keep them clean internally and externally. Likewise, checking and replacing all parts at the set factory-recommended time or mileage limit also help to maintain the good running condition of your VW car.


Taking Care of Your Volkswagen

Brand New Rel Subwoofer

Wednesday, September 28, 2011

What Is A Contactor In An Air Conditioning System? A Bad Contactor Can Lead To Major Failures!

!±8± What Is A Contactor In An Air Conditioning System? A Bad Contactor Can Lead To Major Failures!

A contactor is defined as an electrical relay used to control the flow of power in a circuit. Many people also refer to them as a relay. A relay is actually defined as a device that responds to a small current or voltage change by activating switches or other devices in an electric circuit. In the real world of heating and air conditioning, what this means is a contactor is capable of handling a higher current than a relay. Relays are usually reserved for small pilot duty applications. Most heating and air conditioning service technicians will not call a contactor a relay.

We will be discussing a typical single pole or double pole contactor as would be found in a modern home using a split system gas furnace with air conditioning or a heat pump. Single poles have only one set of contacts while double poles have two. Single poles are used by many manufacturers of equipment. Single poles only break half the power to the fan motor and compressor while double poles break it all. We feel most heating and air conditioning service technicians probably like breaking both sides, at least we do.

Contactors actually have at least two separate circuits in them. (Some commercial contactors have many circuits). One circuit is the low voltage coil circuit and the other is the load circuit.

The coil circuit in MOST home air conditioning or heat pump systems uses a 24 volt coil, however, there are some systems that use a 230 volt coil in conjunction with a small relay that switches the contactor on and off. These 230 volt coil systems are predominantly on older systems or commercial units these days. Before changing any contactor be sure the correct coil voltage is used or a burnt coil may result. The coil voltage will be marked on a small tag on the side of the contactor. The line/load circuit in the home contactor is used to supply 230 volts to the load side of the equipment from the line side. In other words, the main 230 volt power coming from the power source of the home flows across the contacts in the contactor to the line side (compressor, fan motor and any other component) when the coil is energized by a call from the home thermostat for cooling or in a heat pump for cooling or heating. When the thermostat isn't calling for the unit to be running, the coil releases and the contacts open causing the compressor and fan motor to stop.

Thousands of on and off cycles however, cause a couple of problems. The most obvious problem is that the contacts themselves get burnt from constantly arching as they open and close the 230 volt connection. Contacts can actually weld themselves closed after a period of time. These thousands of cycles also cause the plastic sliding mechanism to wear. This wear often causes the contactor contacts to stick closed even though the thermostat has stopped sending an electrical signal to the coil. When this happens it usually goes unnoticed by the homeowner and can quickly lead to a frozen evaporator coil and or compressor. When a frozen condition exists the oil in the compressor is also frozen and can't lubricate the internal parts inside the compressor. This conditions amounts to the same thing as running your vehicle with no oil! The other issue with burnt contacts is that there may be a voltage drop and added heat sent to the compressor and fan motor since the contacts are burnt.

To put things in perspective, changing a contactor is very cheap protection against having to replace a ,000- ,500 compressor. Contacts should be examined every year before operating the unit and usually should be replace every five years or so.


What Is A Contactor In An Air Conditioning System? A Bad Contactor Can Lead To Major Failures!

New Removing Ice Dams

Friday, September 16, 2011

Benefits of Halogen Oven

!±8± Benefits of Halogen Oven

If you're planning a kitchen stove, then you should consider a halogen oven. Halogen ovens used in cooking methods and advanced technologies are able to offer delicious dishes all the time. They are much faster and more compact than a conventional oven.

The biggest advantage of using a halogen oven is portability. Since it is very compact and handy, no need for a large space for storage. You can take him wherever you want and if youDo not use. You can also take them out for all occasions and family gatherings. Even if they are small, they can cook some foods, such as a chicken medium and some vegetables.

The containers are made of glass so you can keep an eye on the food during cooking and adjust the temperature accordingly. Halogen ovens are capable of cooking 40% faster than a conventional oven and you can use to save cooking time. You can save up to 75% of energy from bothCooking food at low temperatures or reducing the total time of cooking. The thermostat controls here can be used to control the temperature between 25 and 250 degrees. They also have a timer to control the cooking time about 60 minutes.

Halogen ovens are really good for cooking chicken is much softer. Most of these are self-cleaning ovens and the glass can be placed on a dishwasher for easy cleaning. Normally, halogen lamps heat the air inside and the air is forced by a fan. Thishot air is transferred through the food and then the food is cooked more evenly. There is no need to thaw the food more, but they can put it directly in the oven for cooking. This contributes significantly to save time. For example, if you buy frozen raw meat or just something clean. If you decide to cook, you can easily put in the oven.

Today, halogen ovens are equipped with many features yet. They find it very convenient, healthy and delicious food in ashort time. They come in many different formats so you can get the ones you get at most. In fact, more than just a little when your family is less than two.

You can also easily the food from the oven, without the need to bend down. You do not need additional oil or fat to cook in these types of furnaces. Taken together with a halogen oven can bake, grill and cook all types of food. Just make your kitchen very interesting and enjoy delicious foodany time!


Benefits of Halogen Oven

Cheap Indoor Bicycle Cheaper Barber Colman Controller Order Parts For Toro Lawn Mowers

Saturday, September 10, 2011

Magic Chef Repair

!±8± Magic Chef Repair

Before obtaining a repair magic chef, you may want to look into some trouble shooting himself. If you have problems with your fridge on some of these:

The refrigerator has stopped

Listening to the side wall to see if you hear a fan or a motor. If you can not then he stopped, his rest only on the basis of the thermostat setting. Before calling a repair technician for Magic Chef, set the thermostat lower back and listen to the engine. Anotherthing to check is the outlet. Put another tool and see if it boots. If it is the electrical device, and yet it does not work, then you could get a repair magic chef. The problems may be with the compressor thermostat, and wiring, defrost timer and overload.

What happens if the cooling is poor? A refrigerator that works, but not cooling very well the problems with the evaporator and condenser coils. If this is the case, you probably need to obtain aRepair.

My Chef magic works, but it is strong.

Listen to see if the noises coming from inside, behind or below. Automatic defrosting refrigerators have an internal fan can be extraordinary strong. You will need to obtain a repair magic chef, if that's the case, because the evaporator fan motor can not be lubricated.

If the noise comes from behind then you may have problems with the compressor, condenser fan motor or the defrost timer. If this isCompressor, which makes the noise then you should replace them.

Sometimes there is a buildup of deposits on the condenser fan and only needs a clean. If this is not the trick then you have to replace the motor.

Sometimes, the electric motor in the defrost timer is strong and the timer must be replaced to solve the problem.


Magic Chef Repair

Track Snow Thrower Fast Best Prices Evening Handbags

Thursday, September 8, 2011

Replacing a thermostat - Wiring Colors

!±8± Replacing a thermostat - Wiring Colors

Replace the thermostat without even Denver HVAC technician can be quite shocking if you do not like the wiring correctly. Inside the thermostat there are several terminals, the need to connect with the right cables. The R terminal is the power thermostat. R means red, in case of artisans Colorado Heating cables are the red to the terminal. This power comes from the transformer. The transformer is normally in the condensing unit or air handler split system.Because they have the power, it is a good idea to kill the power to both the condenser and the air handler before working on the thermostat.

The RC terminal is the power for cooling. Some HVAC systems have two large transformers, one for cooling and heat. In this case, the power system to the terminal ac thermostat. A jumper between RC and RH can be installed for a single transformer heating and cooling. The RC terminal is also red.

The RHTerminal is warming. This is also red and the RC can be skipped.

The Y-terminal is yellow and goes to the compressor relay. Some HVAC Specialists Denver with a terminal strip on the control board air treatment, the bonded joint does not need. Y2 is blue and is usually code for a cooler second stage. If you have two compressors, two should work the thermostat itself. Heating Denver and most airlines do not need one to two cooling stagesCompanies.

W is the terminal heating. W is for white-terminal. This should be directly to any heat source, be it a furnace or boiler. W2 is the second stage of heat and is usually brown. This is for the gas-cooker with low and high settings. Heat pumps use W2 additional heat.

G is for green, and goes to the blower relay inside.

C stands for common and not a specific color, although black is often seen. Consuming digital thermostats, electricity,common line is needed to close the circuit to 24 volts.

Orange "O" and "B" Blue is for heat pumps. Rheem Ruud heat pumps use the terminal B to the cooling valve. Other producers use the HVAC terminal O. Trane, Lennox, Goodman, Ducane, Heil, Carrier, Fedders, Amana, Janitrol and are generally up to the terminal O of HVAC contractors in Denver addiction.

It is equipped for emergencies. This has no color standards, but should the heater relay or e-connect terminalEdge strips.

S1 and S2 are sensors for outdoor air. This has no color standards, but must use a shielded cable to avoid interference and reduce the possibility of damage to the waters outside. Warning: These colors are the default values. The person wiring thermostat can be used non-conventional color coding.


Replacing a thermostat - Wiring Colors

Used Husqvarna 359 Chainsaw Brand New Casio Digital Camera 10mp

Tuesday, September 6, 2011

Flex-a-lite 31165 Variable Speed Control Module

!±8± Flex-a-lite 31165 Variable Speed Control Module

Brand : Flex-a-lite | Rate : | Price : $99.95
Post Date : Sep 06, 2011 18:15:21 | Usually ships in 24 hours


The Flex-a-lite Variable Speed Control Module is an adjustable fan controller that can be set to have your fans come on at any temperature between 160-240F. When fans come on with temperature, they are activated at 60% run using a soft start feature, which greatly reduces startup amperage. As the temp rises about 10 degrees, the controller gradually increases fan speeds up to 100%.

More Specification..!!

Nike Dunk High White Dark Obsidian Discounted


Twitter Facebook Flickr RSS



Français Deutsch Italiano Português
Español 日本語 한국의 中国简体。







Sponsor Links